캐비테이션에 의한 오리피스 인젝터 분사특성 수치해석

배주현, 이형주, 최호진 et al. · 한국추진공학회 학술대회논문집 · 2014

A numerical simulation has been conducted to study the mechansim and effects of cavitation dependent on flow conditions when a heated liquid was injected through an orifice injector. ICEMCFD TM and FLUENT TM were used to generate the mesh and perform the CFD analysis, respectively, for the injector with the diameter of 0.7 mm, through which water was injected at the injection pressure of 3 bar and temperature ranging from 0.1 to 120 ℃, and the results were quantified by flow coefficient, α. The study showed that α decreased at the temperature over 5 0℃ due to the high containment of water vapor caused by more active cavitation at high injection temperature. In addition, the slope of α with respect to cavitation number Kc was very similar to that obtained from a previous experimental study when Kc was below 1.0.

Cited by 0 works.