로켓엔진 고공환경 모사용 디퓨져의 냉각 채널 열 해석

조기주, Yong Oock Kim, 강선일 et al. · 항공우주기술 · 2010

Water cooling ducts are installed in the exhaust diffuser for high altitude tests of rocket engine to protect diffuser from high-temperature combustion gas. The mass flow rate and pressure of cooling water is designed to prevent boiling of cooling water in the ducts. Therefore, the estimation of maximum temperature of duct wall is important parameter in design of cooling system, especially pressure of cooling water. The method for predicting maximum temperatures of duct walls with variation of coolant flow rates was derived theoretically.

Cited by 0 works.