두개강내, 경동맥 협착률 측정 비교분석
김태일, 이원구, 황선문 et al. · 대한인터벤션영상기술학회지 · 2008
Purpose The purpose of this study is to evaluate and compare the degree of stenosis of intracranial artery or carotid bulb using currently available methods. Material and Methods We retrospectively analyzed the degree of stenosis using the QCA and WASID methods in 177 intracranial arteries (basilar artery : 27, intradural ICA : 54, middle cerebral artery : 70 and intradural vertebral artery : 27) of 110 patients(mals : femala=128 : 42, age : 35-78 years) who received stent insertion(n=142) or balloon angioplasty(n=35) between June 2000 and August 2007. For evaluating degree of stenosis at carotid bulb, we applied NASCET and ECST criteria in 217 stenosis of 189 patients(male : female=l48 : 41, age : 45-83 years) who received stent insertion between July 2000 and October 2007. The degree of stenosis was automatically measured by commercial software(CAAS5.4 : Pie Medical Imaging BV, Netherlands) before and after intervention Paired T-test was applied to find any statistical difference between each methods for evaluating stenosis degree in intracranial arteries and carotid bulbs. Results The mean stenosis degree of each intracranial artey before intervention using the QCA and WASID methods were as follows; The BA(QCA : WASID=79.88±1499 : 81.35±14.45), the IC(QCA : WASID=67.96±16.47 : 69.53±16.43), the M1(QCA : WASID=74.82±16.94 : 74.91±16.63), the VA(QCA : WASID=68.77±14.45 : 70.73±14.06). The mean stenosis degree of each intracranial artery after intervention using the QCA and WASID method were as follows : The BA(QCA : WASID=38.96±26.83 : 40.48±26.41), the ICA(QCA : WASID=34.56±24.15 : 35.14±22.47), the M1(QCA : WASID=31.21±23.52 : 30.35±24.35), the VA(QCA : WASID=29.96±16.67 : 28. 35±15.52). There was no significant difference of the degree of stenosis between the QCA and WASID methods (before intervention: p=0.534, after intervention: p=0.529). Carotid bulb stenosis rate measured by the ECST(73.62±13.36) is much higher than the rate measured by the NASCET(67.74±12.59)(p<0.001). After stent insertion stenosis rate measured by the ECST(32.68±13.36) is also much higher than the after stent stenosis rate measured by the NASCET(15.53±13. 52)(p<0.001). Conclusion When we ap plied the QCA and WASID methods for evaluating stenosis degree of intracranial artery, there was no significant difference. However, the degree of stenosis measured by ECST criteria was higher than that of stenosis measured by NASCET criteria in carotid bulb stenosis.
Cited by 0 works.