복합십자형으로 보강한 콘크리트충전 각형기둥-보 접합부의 내진성능에 관한 실험적 연구
최성모, 윤여상, 김요숙 et al. · 대한건축학회 논문집 - 구조계 · 2004
The combined cross connection is one of the details developed for the connection & support of square CFT column and steel beam and is suggested to be used for the structure of asymmetric span ratio. The structural and functional characteristic of this connection lies in the penetration of the beam flange at the side of strong axis (long span side) through the column for the smooth flow of stress in long span beam. The purpose of this study is to analyze the dynamic behavioral characteristics & stress flow of the CFT column-to-beam structure adopting combined cross connection and to evaluate the resistance to shock associated with the connection part. Four T-type CFT column-to-beam specimens using combined cross diaphragm along with interior & through diaphragms, the existing CFT column-to-beam connections, were made for repeated load test guided by the load program of ANSI/AISC SSPEC 2002. The result showed that the proposed connection part is more efficient than existing ones in terms of strength, stress flow & energy absorption and has the resistance against seismic performance required in the region of light/moderate earthquakes.