실내 모형실험을 통한 콘크리트 폐침목 쌓기식 옹벽의 거동특성 분석
문홍득, 정연득 · 한국지반환경공학회 학술발표회논문집 · 2014
Concrete old sleepers can be used as a gravity retaining wall material to resist earth pressure. It builds up with serial and parallel blocks of concrete old sleepers. The old steeper gravity retaining wall is not greatly affected by the ground on the back because this method is stacked in accordance with the shape of the slope. The retaining wall hardly subject to the influence of water pressure because drainage is performed in a space formed at the time of stacking blocks. This stacking is not a method that requires specialized techniques. The advantages of this method are simple construction and short construction period. In this paper, we measured the displacement of the retaining wall according to the loaded weight on the surface. The tests were performed in two models of CASE-1 using only parallel block and CASE-2 using parallel block and serial blocks through the laboratory model tests.