고강도 콘크리트의 부재사이즈 변화에 따른 폭렬특성

정홍근, 손호정, 이보형 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2009

The effect of change in the size of high strength concrete material on spalling was reviewed in this study. The results can be summarized as follows. First for plain mix, peak temperature of 649℃ was exceeded after 60 minutes of heating. While failure area on the surface was found to increase with increasing size of specimen concrete material, all sizes satisfied the peak temperature of 538℃ and mean temperature of 649℃ regulated by the Ministry of Land, Transport and Maritime Affairs. Synthesizing the above results, rational size of concrete material for fire resistance verification needs to be unified to consider the sizes of testing agencies and equality. The size of 700 × 700 was found in this study to be most appropriate.

Cited by 0 works.