휘발성 유기 화학물 실시간 탐지용 박막 센서
최준규, 전은용, 이정훈 · 대한기계학회 춘추학술대회 · 2011
The possibility of mechano-chemical transduction for bio/chemical events have generated wide interest in the expanding applications of genomics, diagnostics, and monitoring environment due to a label-free and realtime technology. For those purposes, most popular technology is a cantilever which has fast, label free, and high sensitive. Furthermore, new paradigm of membrane transducer easily coat probe molecule on the one side of it. At this time, we present a highly reliable thin membrane transducer (TMT) ?based mechanochemical sensing platform fabricated with conventional MEMS process. This device is suspended with thin silicon nitride membrane (100 nm) , lower electrode. The counter electrode is effectively built up on just one wafer. The cavity side of the membrane is coated with thin gold (30 nm) for molecular immobilization and reaction. We confirm the specific reaction of 4, 6- mercapto hexanol molecule with our platform.