전단보강체의 상세에 따른 기초판의 전단성능 평가

양원직, 이원호, 이용재 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2011

Shear head reinforcement method of foundation plate is used shear reinforcement method for flat plate slab in Korean Building Code 2009. Therefore, in case of the shear head reinforcement of foundation plate depth shall not exceed 70 times the web thickness and the flexural stiffness ratio shall not be less than 0.15. However, KBC 2009 does indicate that the depth-thickness ratio do not consider in case of steel buried in concrete due to the concrete to prevent buckling. Therefore, this study shows the result of experimental investigation for the depth-thickness ratio of shear head reinforcement in foundation plate.

Cited by 0 works.