마이크로 열전냉각기의 형상 변화에 따른 냉각성능

이공훈, 김욱중 · 한국태양에너지학회 학술대회논문집 · 2006

In order to figure out the effect of geometry on the cooling performance of the thermoelectric cooler, the parametric analysis has been carried out. Bi2Te3 and Sb₂Te₃ are selected as the nand p-type thermoelectric materials, respectively. The thermoelectric leg considered is 20 ㎛ thick. The effect of parameters such as the current applied to the cooler, the temperature difference, and the arrangement of thermoelectric pairs on the performance of the cooler has been investigated. There is a current at which the COP is maximized and the maximum COP decreases with temperature difference. The number of pairs and the cross-sectional area of thermoelectric leg also affect the performance of the thermoelectric micro-cooler. When the cross-sectional area of the thermoelectric element is small and the number of pairs is large, the cooler can be operated at the relatively low current.

Cited by 0 works.