수평형 스크류식 아이스슬러리 제빙관 내부의 압력상승에 관한 실험적 연구
이상훈, 유호선, 임효묵 et al. · 2012
The propylene glycol solution flowing through the pipe in the horizontal ice slurry maker, with the fall down temperature because of the evaporation of the refrigerant existing outside the horizontal pipe, is transformed into ice slurry. At this time, the screw located within the horizontal pipe keeps on rotating, pushing the formed ice slurry out. If the screw stops functioning on account of a motor failure etc., the already-formed ice slurry is stuck within the pipe and can become more solid ice. In order to check whether, in this kind of situation, the already-formed ice slurry is likely to damage the pipe, this study carried out the measurement of the pressure rise. With one side of the ice slurry maker pipe, within the pipe the screw was stopped, closed with a valve and the other side left open, when the temperature gradually dropped and freezing occurred inside the slurry maker, the resulting volume expansion and the pressure at the closed part were measured. The extent of measured pressure rise and the allowable pressure of the adopted pipe were compared and the possibility of damage by freezing was investigated.
Cited by 0 works.