이중 입구형 맥동관 냉동기에서의 압력 파형 측정
정제헌, 남관우, 정상권 et al. · 2002
Double inlet pulse tube refrigerator was fabricated with o19.0 ㎜ × 125 ㎜ regenerator packed by #200 stainless steel mesh and o12.7 ㎜ × 125 ㎜ pulse tube. A pressure sensor was installed at the inlet of the regenerator and a differential pressure sensor was installed between the inlet of the regenerator and the warm end of the pulse tube. Wave form pulsating pressure was independent of the opening of the orifice and the bypass valves. Helium flow through the orifice valve was calculated based on the measured pressure. Work loss through the orifice valve was evaluated with the measured pressure and the calculated helium flow rate. The work loss, which is equivalent to the refrigeration capacity at the cold end in an ideal pulse tube refrigerator, increased as the opening of the orifice valve increased, but the real refrigerator showed the best performance at the optimized opening of the orifice valve. Helium flow through the bypass was also calculated. Work loss through the bypass valve was not significant.