영구자석 노화에 따른 제어봉 위치지시기의 성능변화 예측

유제용, 김지호, 허형 et al. · 대한기계학회 춘추학술대회 · 2009

The Control Element Drive Mechanism (CEDM) for the integral reactor is designed to raise and lower the control rod in steps of 2㎜ in order to satisfy the design features of the integral reactor which are the soluble boron free operation and the use of a nuclear heating for the reactor start-up. The actual position of the control rod could be achieved to sense the magnet connected to the control rod by the position indicator around the upper pressure housing of CEDM. It is sufficient that the actual position information of control rod at 20㎜ interval from the position indicator is used for the core safety analysis. As the magnet moves upward along the position indicator assembly from the bottom to the top in the upper pressure housing, the output voltage increases linearly step-wise at 0.2VDC increments. Between every step there are transient areas which occur by a contact closing of three reed switches which is the 2-3-2 contact closing sequence. In this paper the output voltage signal corresponding to the position of control rod was estimated on the 2-1-2 contact closing sequence due to the aging of the magnet.

Cited by 0 works.