室內採暖條件下借助作用因子(算符)對圍護結構(牆、窗)保溫控制指標與節能控制指標的確定-建築熱環境與建築節能研究(之六)

黃恒棟 · 2005

On the basis of the interrelated controlling method for the indoor thermal environment and the energy conservation,(superscript [1]) after the controlling indexes of walls for heat preservation[D0](subscript min),. [R0](subscript min), [q(subscript s)](subscript max)(superscript [2]) is given. by means of interrelated acting factor (operator) between window and wall Ψ the controlling indexes of the walls for heat preservation can be transferred into the controlling indexes of the windows for heat preservation [D(subscript s)](subscript min), [R(subscript s)](subscript min), [q(subscript s)](subscript max)(superscript [3]); On the same times, by means of acting factor (operator) for energy conservation of wall (window) Φ the controlling indexes of the walls for heat preservation can be transferred into the Controlling indexes of the walls for energy conservation [D(subscript 0-E)](subscript min), [R(subscript 0-E)](subscript min), [q(subscript 0-E)](subscript max) and the controlling indexes of the windows for heat preservation can be transferred into controlling indexes of the windows for energy conservation [D(subscript 0-E)](subscript min), [R(subscript s-E)](subscript min), [q(subscript s-E)](subscript max) too.