밀폐된 선박 블록의 도장 용제 배출방법에 대한 연구

최민규, 이성균 · 대한기계학회 춘추학술대회 · 2013

This paper presents a new ventilation method and CFD simulation result for solvent vapor in confined spaces. In shipbuilding, a minimum of two coats system has been normally adopted and after the enough drying of the first coat, the application of second coat can be done. A solvent rich atmosphere in a complicated structure can retard drying and causes the coating defects such as delamination. Therefore, the proper ventilation in confined spaces is the one of critical issues in coating process from the standpoint of coating performance, explosion and health. In case of conventional exhaust method using axial fan which is located at block outside, it is not effective for double hull blocks which have commonly complicated internal configuration. The newly proposed ventilation device consists of the jet fan driven by the compressed air, a folding duct and a guide wire for ventilation duct. So, it can effectively exhaust the organic solvent in the confined area by supplying the fresh air to deep inside of the double hull block. CFD analysis was also performed to verify the performance of the new ventilation device. Field test results clearly show that new ventilation system can be a valuable tool for removing the solvent vapor in a complicated structure.

Cited by 0 works.