공동주택 이중창의 결로방지 성능 향상을 위한 실제 규모 성능평가 고찰

최경석, 조선호 · 건축 · 2015

Condensation prevention performance plays significant role in the improvement in occupantss living satisfaction and reduction of defect. Civil complaint about residential environment such as the condensation problems are rapidly increasing by the growing interest in residential environment from improvement of the quality of life. In the case of double glazing window installed for a expanded balcony apartment, the inside window condensation as well as the complaints about the outdoor window condensation is also tendency to surge. This study shows analysis of TDR(Temperature Difference Ratio) for inside window surface and intermediate space air temperature on according to full scale mock-up test. It is found that Case 4(Low-E is located in outside) only it satisfied the requirements TDR conditions(-15℃) and air temperature in intermediate space was significantly increased. The results of this study can significantly contribute to the improvement in condensation prevention performance.

Cited by 0 works.

Authors