태양광 발전 시스템 점검기법 및 현장실태 조사
한운기, 정진수, 안재민 et al. · 대한전기학회 학술대회 논문집 · 2009
Recently solar power system is increasing and planing to add it and 169 up to 2008 year march. In this paper, we researched sites installed PV system and analyzed problems .for improvement of electrical safety. Results of actual condition research on the sites have problems such as infiltration of moisture, aging of electrode, destruction of insulation and backsheet crack and so on. So we suggest maintenance guide of solar power system in a inspection statistical chart, For making a secure about a electrical safety, we should inspect solar power system by the KESCO guide and rule by periods.