중온 범위 태양열 집열기용 히트파이프의 성능 시험

부준홍, 정환수, 곽희열 et al. · 한국태양에너지학회 학술대회논문집 · 1999

A slab-wick heat pipe was fabricated and tested for applications where the condenser temperature in the range of 80 to 120℃. The pipe material was 9.53 ㎜ o.d. copper tube and the working fluid was ethanol. The slab was fabricated in combination of 20 mesh and 200 mesh stainless steel wire screens. The total length of the heat pipe was 1500 ㎜ in which evaporator section was 1300 ㎜ and the condenser was only 150 ㎜. Fluid charge ratio and inclination angle were varied with applied thermal load. Optimum charge ratio was identified and the maximum thermal load was 120 W with condenser temperature of 120℃. The thermal performance of the slab-wick heat pipe is analysed and discussed in terms of temperature, thermal conductance, and transient performance with varying thermal load.