초고층 공동주택에서 배기겸용 풍력발전 적용을 위한 기류분석 연구

박정하, 김진우, 장호진 et al. · 대한설비공학회 하계학술발표회 논문집 · 2011

Recently, high-rise apartment is being briskly built but there has problems such as lack of ventilation, stack effect and energy consumption. Therefore It is needed to develop of Small Wind Power System Combined Ventilator as measures to solve these problems. The purpose of this study is to provide basis for Small Wind Power System Combined Ventilator in super high-rise apartment. This study conducted CFD simulation (Star-CCM) by building height and distance of two structures for knowing the effect of wind speed increase when the structure is installed. As a result, the best place was in front of the roof for main wind direction, and the best building height was 200m rather than 300m. If two or more small wind turbine combined ventilator were installed closely, vertical position for main wind direction was recommened. Horizontal position must necessarily be avoided, but height differnece between two blades is more than 3m, was good performance result.