공동주택 바닥 복사냉방 시스템을 위한 제습형 보조냉방기의 대표실 적용 평가

오혜원, 정창호, 이진영 et al. · 한국건축친환경설비학회 학술발표대회 논문집 · 2010

In order to apply radiant floor cooling system in a residential building, it is required to install dehumidification/sub-cooling equipment according to the characteristics of cooling load. But it may not be appropriate to install dehumidification/sub-cooling equipment in every room because of cost and system operation efficiency. So it might be considered to install dehumidification/sub-cooling equipment only in the representative room. In this study, therefore, preventing condensation/sub-cooling performance for each room were evaluated through the field experiment in this condition. The results show that preventing condensation/sub-cooling performance for each room is more influenced by door's open/close than distance to the system. In most cases, preventing condensation/sub-cooling performance were satisfied, but it can be concluded that it is better to install dehumidification/sub-cooling unit separately if dehumidification load of a room is expected to be large.

Cited by 0 works.

Authors