철골보-기둥 용접 접합부의 초기강성에 관한 연구

손상해, 김순태, 유병억 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2003

The purpose of this study was to propose the initial stiffness of steel welded beam-to-column connection. To simplify the analysis, neglect the influence of welding and fillet of H-section beam. According to the parameter(ζ), initial stiffness(Ki) increased by ratio of section modulus(Zb/Zc) and decreased by ratio of width/thickness. Result of analysis, range of moment resistance is 0.50Mf~1.00Mf(Unstiffened Welded Connection), 0.77Mf~1.00Mf(Continuity Plates Welded Connection) and initial stiffness(Ki) is 1.36x100000000~24.5x100000000(kgf·cm)(Unstiffened Welded Connection) 3.79x100000000~33.3x100000000(kgf·cm)(Continuity Plates Welded Connection).