복합유동 발생 지지격자 후방 봉다발에서의 유동 구조 측정

오동석 · 대한설비공학회 동계학술발표회 논문집 · 2001

An experimental investigation of the flow structures in rod bundles with the air test model for the hybrid spacer grid has been performed. Three dimensional velocity distributions and turbulent intensities in central subchannel are measured at the Reynolds number of 1.2 × 10^5 by using pitot tube and hot wire anemometry. The rods were arranged in a square array with a pitch to diameter ration of 1.33. The flow downstream in the central subchannel with hybrid spacer grid appears to be swirl flow, but in the rod gap regions cross flow is encountered. The main swirl flow is to impact on the rod surface after x/Dh=2. The highest axial turbulent intensity, which is similar magnitude with the previous results for split vaned grid, is observed at center of subchannel and decreases as near to gap and rod.

Cited by 0 works.

Authors