전기철도 터널구간 애자류 오염도 분석 연구
전용주, 이기천, 이시빈 et al. · 한국철도학회 학술발표대회논문집 · 2009
This paper introduces insulator pollutant accumulate characteristic in the tunnel of korea railroad. To accomplish this goal, effective sample collecting method was proposed for the first step. Direct dust collecting method was selected. Distilled water and brush was used while collecting. The second step is pollutant analysis. Several analyze item is selected such as quantity, conductivity, contact angle, Optical Microscope(OM), Equivalent Salt Deposit Density(ESDD), and ICP-AES. The third step, best represent tunnel was selected considering location, length and natural surroundings. Also to consider the difference at inside the tunnel, several bracket insulators were selected along to the location. To make the result precise, above procedure was repeated several times at the same target. Finally relation among type of train, numbers of movement, surroundings, length will be considered in combination with the pollution. With this result pollute map for the tunnel could be accomplished and inspect period will be optimized case by case