접합분리 시험체를 활용한 고강도 콘크리트의 강도관리
기전도, 김학영, 이영도 et al. · 대한건축학회 논문집 - 구조계 · 2010
The existing techniques used to estimate and manage the compressive strength of concrete do not include the environmental factors that influence the development character of compressive strength and the compressive strength itself. Thus, it is necessary to develop a reasonable yet simple way to measure the compressive strength of concrete structures at construction sites by considering concrete's mechanical properties and curing environment. This study was conducted to propose an acrylic form and a junction isolation mold with crack-inducing boards that uses non-destructive methods to create and collect concrete test samples that are cured in the same condition as the actual concrete structures. junction isolation molds were used in high-strength and super high-strength concrete to evaluate the reliability of compressive strength evaluation on the test sample. The following were the findings of this study.
Cited by 0 works.