현장에서 초음파 파쇄와 형광시약을 이용한 단백질 독소의 조기 탐지
하연철, 최기봉, 김성주 et al. · KSBB Journal · 2007
This study was carried out to establish the optimum disruption condition of a sonificator for the protein toxin for the purpose of developing automatic biological agent detector equipped a sonificator. One of the best-known collisional quenchers is molecular oxygen, which quenches almost all known fluorophores. The sonification does an excellent job of degassing, which decreased the quenching effect and increased the fluorescence quantity. The fluorescence measurement for the protein using 0.7 X fluorescent dye concentration and above must be done in 1 minute and the fluorescence measurement for the protein using 0.3 X fluorescent dye concentration and below has to be done between 2 and 3 minute. The fluorescence quantity of the sonificatied protein sample was much higher that of the non-sonificatied protein sample. Sonificating the sample turned out to be favorable for the fluorescence measurement when measuring at the low protein concentration.
Cited by 0 works.