개방수조형 연구용 원자로의 출력 증가에 따른 고온층 열손실 특성

박용철, 지대영, 서경우 et al. · 대한기계학회 춘추학술대회 · 2010

During an open-tank-in-pool type research reactor operation, the primary coolant was designed to remove the fission reaction heat of the reactor. When the primary coolant flew upward or downward the core by the driving force of the primary coolant pump to cool the heat generated by the reactor, a part of the primary coolant which did not pass the core reached the top of the reactor pool by a natural convection. And it increased the radiation level at the top of the pool. To protect a natural convection of the core bypass flow, a hot water layer (hereafter as HWL) was installed in the top of the pool. To maintain the HWL, the heat loss is calculated and evaluated based on the HANARO HWL calculation model as per the reactor power increment. It was confirmed through this study that it is available to find a relation formula for predicting a total heat loss for each flow condition as per the reactor power increment.

Cited by 0 works.

Authors