전기히터방식 매연여과장치의 재생특성 향상을 위한 흡기드로틀링 연구
김홍석, 한승환, 조규백 et al. · 한국자동차공학회 춘 추계 학술대회 논문집 · 2004
Application of an electric heater to a DPF system is one of attractive methods for active regeneration, but limitation of electric power available in vehicles has been a problem to be solved. In this study, intake throttling was studied to reduce the required electric energy of an electric heated DPF system. This study showed the decrease of 30-50% of intake air mass flow rate and increase of 20-60℃ of exhaust gas temperature by the intake throttling. When intake throttling was applied with the condition of EGR OFF, required electric energy for soot regeneration was reduced due to the effect of exhaust gas temperature increase.