하나로 핵연료시험설비의 비상냉각수계통 성능 예측 평가모델 분석
박수기, Bong Shick Sim, 박국남 et al. · 대한기계학회 춘추학술대회 · 2006
The performance of the emergency cooling water system of the HANARO fuel test loop has been predicted with the MARS code. Evaluation models such as the Moody model for discharge rate calculation and the Baker-Just model for water-metal reaction calculation were used. Multipliers were also introduced to the correlations of heat transfer coefficients in the MARS code in order to calculate conservative peak cladding temperatures for accidents. The maximum peak cladding temperature is calculated for the longitudinal split of the cold leg in the HANARO pool and greatly depends on the multipliers of the critical heat flux and film boiling correlations. In the analyses the issue on return-to-nucleate boiling phenomena, after critical heat flux is first predicted at an axial fuel rod location during blowdown, is not important for predicting the maximum peak cladding temperature.