장대 교통터널 화재시 임계속도 결정에 관한 실험적 연구

윤찬훈, 윤성욱, 유용호 et al. · 한국암반공학회 학술대회 및 세미나 자료집 · 2006

In this study, scaled model tests were carried out to decide the optimal critical velocity, to prevent back layering in the case of fire in a long traffic tunnel. Realistic estimates were made for the time required for people to escape from the tunnel and for the time required by the ventilation operator to increase the system speed to full capacity. The analysis, predicts that the emergency ventilation will start about 240 seconds after the tunnel fire. It was also found that prevention of back layering would occur within 4 minutes after fan operation. To find out optimal critical velocity, a 1/50 scaled model tunnel(diameter : 0.2 m and length: 20 m) based on the Froude similarity technique was constructed. Changing β values in the Tetzner's equation, smoke propagation was observed. From the experiment, it was concluded that using a β value of 0.5 to prevent back layering successfully allowed time for safe evacuation.

Cited by 1 works.