수직하중 및 횡하중의 영향을 받는 포스트 텐션 플랫 플레이트 내부 접합부의 횡변형 능력에 관한 실험적 연구
기성훈, 하상수, 한상환 et al. · 대한건축학회 학술발표대회 논문집 - 구조계 · 2004
In North America, Post Tension Flat Plate Slab is widely used in the high-rise office or residential building as a GLRS(Gravity Load Resisting System). Although flat plate slabs have a number of advantages, more care should be required regarding punching failure. Generally, flat plate system is designed as GLRS(Gravity Load Resisting System). Even such members designed for only gravity load, due to drift of primary LFRS(Lateral Load Resisting System) caused by earthquake or wind, go through same drift. Therefore, it is required to check a sufficient lateral deformation capacity of GLRS such as flat Plate slabs for a appropriate stability of structure in severe condition. According to various experimental results of slab column connections, gravity load is a most significant variable and which should be lower than 0.4Vc to satisfy the lateral drift of 1.5% of drift ratio; generally applied as a drift limit in the seismic design is 1/5%~2.0%. This is available to PT flat plate as it is. Moreover, compressive stress caused by pre-stressing tension contributes to better lateral deformation capacity of PT flat plate. However, due to insufficient experimental data of PT flat plate, same provision on control of lateral drift capacity is provided; it seams to be somewhat conservative. The purpose of this research is to assess a lateral drift capacity of PT flat plate by means of experimental investigation of behavior, failure mechanism, strength and ductility of PT flat plate under constant gravity load and monotonic quasi static uniaxial lateral load.