고속전철 여압장치 성능시험

염한길, 고득용, 박성제 et al. · 2000

Atmospheric pressure in a tunnel rises in proportion to the square of train's speed as it enters a tunnel. This pressure difference propagates into the train and cause aural discomfort to the passengers. In order to alleviate the aural discomfort of them, a new pressurization system has been designed and tested. Inside pressure of train is controled by supply/exhaust fan and control valve to near the atmospheric pressure. In this study, three control algorithms are tested. First, fan rpm is step control and supply/exhaust valve is PID control. In this case, pressurization system is not to be satisfied design performance. Second, fan rpm is constant and supply/exhaust valve is PID control. In this case, performance is to be satisfied but there is power consumption and durability problem. In the last, fan rpm is function control and supply/exhaust valve is PID control. In this case, all of them is satisfied.

Cited by 0 works.