직접 구동형 동기발전기 고정자의 열전달 거동 특성
안대균, 우은택, 조윤현 et al. · 대한기계학회 춘추학술대회 · 2013
For the sustainable development of wind energy, the energy industries have invested in the development of highly efficient wind generator such as an axial flux permanent magnet(AFPM) generator. The AFPM generator, however, has a history of overheating on the stator surface, so that power production decreases significantly. A proper cooling system, therefore, is needed. Although in the case of low capacity generator, a convective-type cooling system has been developed, the size of the air blower must be increased when the generator’s capacity exceeds 2.5MW. In this study, a newly developed conductive-type cooling system was proposed for the 2.5MW AFPM generator installed on an offshore wind turbine. Through electromagnetic-thermal analysis, the characteristics of the heat transfer in the generator were investigated. For the application of the proposed cooling system, the temperatures on the surfaces of stator and permanent magnet were 86 and 68℃, respectively, which could not affect the decrease of the power production efficiency.(KETEP 20134030200320)