접촉 및 비접촉된 헤드 철근의 겹침이음 성능에 관한 실험적 연구
이용택, 채서호, 김승훈 et al. · 한국구조물진단유지관리공학회 학술발표회 논문집 · 2005
Headed bars have used to the anchoring of the tension or compression longitudinal bars and of the shear reinforcing bars. Recently, lap splices of headed bars are attempted to the joints of precast concrete members and to the connections between old and new concrete members. It is desirable that the headed ends protruding from two adjoining precast segments be offset from one another as much as possible so that overlapping is avoided and placement. In this study, the lap splice performances of contact and non-contact headed bars are evaluated through the experimental works. Six specimens, of which variables were the spacing of lapped bars and the type of confine details. Test results show that the confine details change the lap splice performance of contact and non-contact headed bars.
Cited by 0 works.