Расчетно-экспериментальное исследование теплового состояния перфорированной стенки жаровой трубы с наклонными щелями
В. П. Лукаш, А. И. Майорова, А. Д. Рекин et al. · Вестник Самарского государственного аэрокосмического университета им. академика С.П. Королёва (национального исследовательского университета) · 2014
The thermal state of a perforated wall with inclined slots for liners was determined experimentally by means of a thermovision system. Three-dimensional calculations of boundary layer aerodynamics on the wall with cooling air injection through discrete inclined slots were carried out on the basis of numerical integration of a three-dimensional system of Navier-Stokes equations. It is established that the cooler jest penetrate into a hot stream less intensively with fan air supply than with straight supply. Consequently, the wall is cooled more efficiently with fan air supply. Dependence of cooling efficiency on the angle of inclined slots was obtained.