축소모델 객차 내 화재위치에 따른 열방출율 영향에 대한 실험

김동운, 박원희, 이덕희 et al. · 한국철도학회 학술발표대회논문집 · 2010

In this study fire behavior and heat release rate are analyzed in a 1/10 reduced-scale subway train for various fire locations. The dimension of the reduced-scale subway train with insulation materials is 1.9 m long, 0.235 m wide and 0.290 m high. The interior materials of reduced-scale subway train are composed 0.003m width plywood. The fire source is used n-heptane pool fire of 0.04 m x 0.04 m and 0.02 m high with heat release rate 2.33 kW. One-sided all four doors of the subway train are opened. The fire locations are the center, near to second door opposite and near gangway in reduced-scale subway train respectively. The temperature, heat release rate and mass loss rate in train are measured until fire was extinguished.