건물의 다목적 외피 시스템의 운전 방법
김의종, 이강영, 서승직 · 대한건축학회 학술발표대회 논문집 - 계획계 · 2005
The Multipurpose Envelope System(MES) was evaluated as an effective passive system through analyzing the thermal performance and the efficiency of PV power generation in the previous paper. To achieve the performance better, the operation method should be determined by considering physical conditions in each occasion. Thus, we choosed the optimal operation method by comparing each system factor with others in a heating period, existing exclusive operation methods of MES, and heating loads and the angle of the roof devices were also considered. The result was that 45° of the tiled angle of PV roof was a profer figure, and heating loads were more critical rather than PV power generation in MES during a heating period.
Cited by 0 works.