분무형 공기정화시스템의 가스제거성능에 관한 연구
유성연, 송준, 권화길 et al. · 대한설비공학회 학술발표대회논문집 · 2001
Gas removal efficiency of spray type air purifying system has been studied experimentally, which can be used along with chemical filter in the clean room in order to extend the life cycle of expensive filter. Experimental apparatus comprises wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller and data acquisition system. Air flow rate, water flow rate, and water temperature, etc. are varied to investigate their effects on the performance of spray type air purifying system. Dependence of density of ammonia ion in the circulated water on removal efficiency is also analyzed.