가압경수로형 원전 급수가열기 출구헤더 연결배관에 대한 국부감육 원인분석에 관한 연구

황경모, 이찬규 · 대한기계학회 춘추학술대회 · 2011

Carbon steel piping exposed to flowing high temperature, high pressure, and high speed water or wet steam experience wall thinning phenomena. Wall thinning damages caused by FAC (Flow Accelerated Corrosion) may be generated in the piping of ordinary industry plants, fossil power plants, and nuclear power plants. The pipe wall thinning in nuclear power plants should be considered more strictly than that of other plants. This is because the pipe wall thinning leads to leakage, rupture, and unplanned shutdown in nuclear power plants, which can affect plant reliability and safety. This paper describes the cause analysis result of local wall thinning for the piping connected to the outlet header of a feedwater heater installed in a PWR nuclear power plant. The results are based on the flow behaviors inside piping simulated by numerical analysis and the UT thickness data analysis.

Cited by 0 works.

Authors