다중균열이 존재하는 증기발생기 세관의 소성붕괴 해석

문성인, Yoon‐Seok Chang, Young Jin Kim et al. · 대한기계학회 춘추학술대회 · 2004

The 40% of wall thickness criterion, which is generally used for the plugging of steam generator tubes, is applied only to a single crack. In the previous study, a total number of 10 local failure prediction models were introduced to estimate the coalescence load of two collinear through-wall cracks and the reaction force model and plastic zone contact model were selected as optimum ones. The objective of this study is to estimate the coalescence load of two collinear through-wall cracks in steam generator tube by using the optimum local failure prediction models. In order to investigate the applicability of the optimum local failure prediction models, a series of plastic collapse tests and corresponding finite element analyses for two collinear through-wall cracks in steam generator tube were carried out. Thereby, the applicability of the optimum local failure prediction models was verified and finally a coalescence evaluation diagram which can be used to determine whether the adjacent cracks detected by NDE coalesce or not was developed.