틈새 장벽을 이용한 효과적인 오존 발생
文在德, 鄭在勝 · 전기학회논문지 C · 2006
In this paper a new wire-wire discharge system with a slit dielectric barrier has been proposed, and, its corona discharge and ozone generation characteristics have been investigated experimentally. When the slit mica barrier is installed between corona wires, instead of the grounded plate electrode, a significant increase in the generation of ozone, about 2.2 times higher than that of the conventional ones without the slit barrier, could be obtained. Photographs show that this type of discharge system with a slit barrier was found to produce a corona discharge twice, once from the upper and bottom corona wires. and. again from both sides of surfaces and slits of the slit barrier. As a result, the proposed discharge system has the potential to increase significantly ozone production and it may be useful as an effective means for removing pollutant gases.
Cited by 0 works.