립이 설치된 수평채널의 압력강하 및 열전달 특성에 관한 수치해석
Ji Hoon Kim, 허주녕, 손영석 et al. · 대한기계학회 춘추학술대회 · 2011
In this study, simulations of turbulent flow and heat transfer in a channel with a detached rib array have been conducted. Air is the working fluid with the flow rate in term of Reynolds numbers ranging from 8,900 to 35,000. The forms of ribs considered in this study were ribs with rectangular cross section, ribs with groove, broken ribs, and V-shaped ribs. The ribs were deployed transverse or aligned 60?to the main direction of the flow. Local heat transfer coefficients were obtained at various Reynolds numbers within the turbulent flow regime. Area-averaged data were calculated in order to compare the overall performance of the tested ribbed surfaces and to evaluate the degree of heat transfer enhancement induced by the ribs with respect to the smooth channel. The highest heat transfer occurred for the rib with groove was aligned 60?to the main flow direction.
Cited by 0 works.