수평미세관내 순수냉매의 비등열전달에 미치는 관경의 영향

윤국영, 최광일, 오종택 · 대한설비공학회 동계학술발표회 논문집 · 2001

The effect of tube diameter on boiling heat transfer for R-22 were measured in horizontal micro-channels. The test section is stainless steel tube, inner tube diameter are 1.8 ㎜ and 2.8 ㎜, the respective length is 1500 ㎜ and 3000 ㎜. The range of mass flux is 300~600㎏/㎡s, and heat flux is 5~15㎾/㎡. The effects of inner tube diameter were clearly observed. Namely, the measured pressure drop inside 1.8 ㎜ I.D. is higher than 2.8 ㎜ I.D. with increasing the mass flux and heat flux. Also, the measured local heat transfer coefficient inside 1.8 ㎜ I.D. is higher than 2.8 ㎜ I.D. in the range of high qualities, a relatively high mass flux and heat flux. But the size of inner tube diameters did not affection heat transfer coefficient in the range of low qualities.

Cited by 0 works.