伝統的背負い梯子「背板」はどのように身体にフィットしているか
雅典 河原 · Kyushu University Institutional Repository (QIR) (Kyushu University) · 1999
Seita is a traditional carrier frame for back packing used in Nishiki-cho, Yamaguchi Prefecture, Japan. In the mountainous district, people make their living by agriculture and forestry, and carry everything on their back with seitas. The purpose of this study was to investingate the relationships between th ebady and seita from different angles. First, the interviews with seita-carriers made it clear how to make a seita, and that particularly some parts of a seita were thought to be fitted to their bodies. Thoughthey had carried incredibly heavy loads with their seitas, there were no complaint about disorders caused by heavy load carriage. Next, I measured some anthropometric sizes and seita dimensions, and specified where the load-supporting point of seita contacted to the lumbosacral area of the body with the use of photographs. The date of this survey make it clear that when people carry loads with seitas, theysupport loads not on lumbar vertebrae but on sacrum, and that they adjust the lenght of the perimeter consisted of bakd part and shoulder strap of seita. The question then arose about th edifference between carrying a load on the sacrum(LOS) and on the lumbar vertevrae (LOL). The experimentwas held to verify the difference between LOS and LOL in oxygen uptake, muscle activities, heart rate, cadence, and subjective response. The following s were signigicantly lowere in LOS than in LOL: cadence, and rated perceived exertion. However IEMG of th eerector spinae was signigicantly higher in LOS than in LOL. These results suggest that seita-fitting in LOS causes a decrease of the leg muscle activities, which causes to decrease oxygen uptake beyond the increase of the erector spinae activity. Further experiments wereheld to verify the difference between LOS and LOL dynamically. The body seay in LOS was significantly smaller than in LOL. The dynamic gaitpettern in both conditions were examined with a force plate. In LOS, subjects kicked the force plate more strongly to walk forward than in LOL. The gate pattern in LOS could keep similar to the cordinary gait pattern. In LOL, subjects walked with gliding steps. The tension of shoulder strap and the force loaded on the lumbosacral area in LOS were lower than in LOL. It follows trom what has been said that a seita was well-fitted to the body to carry a heavy load, and that the fitting method i.e. to support a load on sacrum with a seita was rational physiologically and dynamically.
Cited by 0 works. doi:10.11501/3148614