두 대의 펌프가 병렬로 설치되는 계통에서의 유량 특성
박용철, 지대영, 서경우 et al. · 한국전산유체공학회 학술대회논문집 · 2011
During a reactor normal operation, a primary coolant was designed to remove the fission reaction heat of the reactor. When one pump is failure and the other pump shall supply the cooling water to cool the reduced power, it is necessary to estimate how much flow will be supplied to cool the reactor. We carried a flow net work analysis for two parallel pumping system as based on the piping net work of the primary cooling system in HANARO. As result, it is estimated thai the flow of one pump increased than the rated flow of the pump below the cavitation critical flow.