이산화탄소의 수직원관 내 상향유동 증발열전달 특성에 관한 연구
김용진, 조진민, Min-Soo Kim · 대한기계학회 춘추학술대회 · 2007
Because of the ozone layer depletion and global warming, new alternative refrigerants are being developed. In this study, evaporation heat transfer characteristics of carbon dioxide flowing upward in a vertical tube have been investigated by experiment. Before the test section, a pre-heater is installed to adjust the inlet quality of the refrigerant to a desired value. A smooth tube with outer diameter of 5 ㎜ and length of 1.44 m was selected as a test tube. The test was conducted at mass fluxes of 212 to 530 ㎏/㎡s, saturation temperature of -5 to 20℃, and heat fluxes of 20 to 45 ㎾/㎡. As the vapor quality and mass fluxes increase, the heat transfer coefficients of carbon dioxide are decreased, and the heat transfer coefficients increase when the heat fluxes and saturation temperatures increase.
Cited by 0 works.