열쾌적성을 고려한 지붕 파라펫 설계연구

박성중 · 한국생태환경건축학회 학술발표대회 논문집 · 2013

External insulation system in Buildings makes a thermal bridge within balcony, external shading structure, roof parpet etc. In this case, Linear thermal transmittance of typical thermal bridges in building envelope was evaluated in surface low temperature point in regard of comfortable environment, the risk of inside surface condensation and mold growth humidity. In this Study, the typical model for linear thermal transmittance of wall-roof junction with both external insulation is suggested, which showed a good result with that from 2D heat transfer simulation. This result is calculated with a simulation tool HEAT2.7, which based on the International Organization for Standardization 10211-1 and 10211-2.

Cited by 0 works.

Authors