경사평활관 내 이산화탄소의 상향유동 증발열전달 특성에 관한 실험적 연구

김용진, 조진민, 이재승 et al. · 대한기계학회 춘추학술대회 · 2008

The ozone layer depletion and global warming has driven us to develop new alternative refrigerants. As the carbon dioxide is believed as a good alternative, evaporation heat transfer characteristics of carbon dioxide flowing upward in an inclined smooth tube(45? have been investigated by experiment. A pre-heater is installed to adjust the inlet quality of the refrigerant to get a desired value before the test section. An inclined smooth tube(45? with outer diameter of 5 ㎜ and length of 1.44 m was selected as a test tube. The test was conducted at mass fluxes of 318 to 530 ㎏/㎡s, saturation temperatures of -5 to 20℃, and heat fluxes of 15 to 45 ㎾/㎡ As the vapor quality increases, the heat transfer coefficients of carbon dioxide are slightly decreased, and the heat transfer coefficients increase with the heat fluxes and saturation temperatures elevated.

Cited by 0 works.