The multiple researches were performed for development of system for individual dosimetric planning of radioiodine therapy of patients with thyroid diseases. The series of scintigraphic (with 1231) and radiometric (with 1311) researches for accumulation-deducing of radioiodine in thyroid of patients with disease were led: Grave's disease (122 patients) and a toxic nodular goiter (36 patiens). Techniques, algorithms and the software for identification of kinetic parameters of radioiodine and calculation of the absorbed dozes in tissues and organs were received on the basis of multichamber models. The statistical analysis of efficiency of radioiodine therapy were led with determined absorbed dose and data received from clinic-diagnostic inspections of these patients in Medical Radiological Scientific Centre in Russian Academy of Medical Science and.