응축부 냉각 용량 변화가 루프식 히트파이프의 성능에 미치는 영향
부준홍, 천만석 · 1998
The thermal performance of a loop heat pipe was investigated with respect to condenser cooling performance. The evaporator and condenser were separated by a distance of 1.2m and were connected by individual liquid and vapor lines. The wall material was copper and the working fluid was ethanol. The experimental facility utilized a combination of capillary and gravitational forces for liquid return, and distribution over the evaporator surface. The tubing used for the vapor and liquid lines was 0.935 ㎝ or less in diameter and heat removal from the condenser was by convection of air. A heat flux of up to 4.9 × 10⁴ W/㎡ was applied to a flat evaporator. The thermal resistance of the system was investigated as the evaporator heat flux and the condenser cooling capacity varied.