보일러 기동정지 운전중의 열응력 시뮬레이션
이지문, 주철홍 · 대한기계학회 춘추학술대회 · 2003
Boiler components of fossil power plant are operated under the severe stresses resulted from high temperature and high pressure during startup and shutdown. While steam temperatures through components abruptly change from low temperature and high temperature, thermal stresses reach the design limit at the same time and reduce the remaining life of components. In general, these stresses are calculated with the commercial programs such as ANSYS and ABACUS. But these calculations are time-consuming and expensive. This paper says that simple and quick simulation during boiler startup and shutdown is developed with Green's Function and the optimum curve is calculated with this program. Green's function is the thermal stress by the unit change of steam temperature. This method is useful of the thermal stress simulation at the startup/shutdown.
Cited by 0 works.