외란 관측기를 이용한 새로운 데드 타임 보상법
김현수, 문형태, 김명복 et al. · 전력전자학술대회논문집 · 1999
A new dead-time compensation method using a disturbance observer is proposed the dead-time causes the voltage distortion and It can be considered as the disturbance voltage in this paper, the disturbance voltage is estimated by minimal order observer m the d-q frame and the estimated disturbance voltage IS summed with voltage command by a feed-forward. The experiments are earned out DSP-based BLDC motor drive system results show the effectiveness of the method. for the and the proposed
Cited by 0 works.